Loopback remote v54 – ADTRAN 1000R Series User Manual

Page 602

Advertising
background image

Command Reference Guide

E1 Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

602

loopback remote v54

The loopback remote v54 command initiates an E1 remote loopback test (with a V.54 loopback pattern).
Use the no form of this command to disable this feature.

Syntax Description

No subcommands.

Default Values

No default value is necessary for this command.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.

Command History

Release 6.1

Command was introduced.

Functional Notes

This command causes a V.54 inband loop code to be sent in the payload towards the far end.

Usage Examples

The following example sends a V.54 inband loop code to the far end:

(config)#interface e1 1/1

(config-e1 1/1)#loopback remote v54