Wiring Power for your Feedback Device (Analog Systems Only)

The control supports feedback devices with 5v compatible output signals.

The voltage that these feedback devices require may vary. The processor

module is equipped to supply 5V dc power to feedback devices. These

voltages may be accessed directly from the encoder termination panel

If your feedback device requires an external power supply, it may be easily

incorporated through the EXT. POWER connector on the termination

panel. Power is then output through the ENC POWER connector terminal

labeled EX PWR OUT. The following figure shows the termination panel

connection for EXT. POWER. Refer to page 7A-1 for details on wiring to

ENC POWER.

Figure 3A.15

Wiring Optional Customer Supplied Power Supply for Feedback Devices

Te

rm

Pa

ne

l

EXT.

POWER

EXT PWR IN
EXT RET IN

Optional

Customer Supplied

Power Supply

External Power

Ground

Shield

11308-I