1

19

20

37

Section 9A

Operator Interface

9A-23

Pin

number:

Description:

Pin

number:

Description:

1

Shld. Chassis Ground

20

Ground

2

Keyboard Data

21

Video Hi

3

Keyboard Data

22

Video Lo

4

Keyboard Data

23

H -- Sync Hi

5

Keyboard Data

24

H -- Sync Lo

6

Keyboard Data

25

V -- Sync Hi

7

Keyboard Data

26

V -- Sync Lo

8

Keyboard Data

27

Ground

9

Keyboard Data

28

12 Vdc

10

Keyboard Data

29

12 Vdc

11

Keyboard Data

30

12 Vdc

12

Keyboard Data

31

12 Vdc

13

Keyboard Data

32

12 Vdc

14

Keyboard Data

33

Ground

15

Keyboard Data

34

Ground

16

Keyboard Data

35

Ground

17

Keyboard Data

36

No Connection

18

Keyboard Data

37

No Connection

19

Keyboard Data

If your machine layout calls for more than one location to plug in your
removable operator panel, read this section. Multiple operator panel

locations typically require a separate removable operator panel interface

assembly at each location. A maximum of four interface modules can exist

in the 9/Series fiber optic I/O ring.

The interface assembly provides power to the CRT as well as a keyboard

interface to the fiber optic ring.

Important: It is possible to place a mounted fixed location operator panel

on the ring with a removable operator interface assembly at some other

location. Call your Allen Bradley support group for details on installing

this type of system.

For systems with two removable operator panel interface assemblies:

Wire the power supplies for both interface assemblies

Connect the KBI interface to the fiber optic ring for both assemblies

9A.3.3

Multiple Removable

Operator Panel Assemblies