4b.7 encoder termination panel – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 187

Section 4B
Connecting the 3-axis Servo Module
4B-41
The encoder termination panels are options with the analog system that
provide an easy and convenient means for you to connect and troubleshoot
your servo system. We strongly recommend the use of termination panels
when installing an analog system.
Termination panels feature:
D-shell connectors for cables from the motion controller (A-B cable
number 8520-TPC)
Plug-type connectors for wiring to user devices
DIN Rail Mountable
All user connections with the exception of the ANALOG OUT (TB2) and
BAT/TP (TB1) connections are routed through the termination panels.
User side voltages of +5V dc and +15V dc for encoder power (chosen by
wiring to the appropriate connector pin) are available on-board. External
power supplies for the encoders may also be routed through the
termination panel (refer to the feedback section).
Figure 4B.35 shows an encoder termination panel.
Figure 4B.35
Encoder Termination Panel
AXIS
DRIVE
DRIVE
RET
SHLD
ENCODER
ENC POWER
CH A. HI
CH A. LO
AB SHLD
CH B. HI
CH B. LO
Z SHLD
CH Z. HI
CH Z. LO
EXT
POWER
+5V
RET
+15V
EX PWR OUT
SHLD
EX PWR IN
EX RET IN
FDBK IO
FDBK IO
RET
SHLD
91670401
1771HTE ENCODER TERMINATION PANEL
11305-I
4B.7
Encoder Termination Panel