Section 4B

Connecting the 3-axis Servo Module

4B-41

The encoder termination panels are options with the analog system that

provide an easy and convenient means for you to connect and troubleshoot

your servo system. We strongly recommend the use of termination panels

when installing an analog system.

Termination panels feature:

D-shell connectors for cables from the motion controller (A-B cable
number 8520-TPC)

Plug-type connectors for wiring to user devices
DIN Rail Mountable

All user connections with the exception of the ANALOG OUT (TB2) and

BAT/TP (TB1) connections are routed through the termination panels.

User side voltages of +5V dc and +15V dc for encoder power (chosen by

wiring to the appropriate connector pin) are available on-board. External

power supplies for the encoders may also be routed through the

termination panel (refer to the feedback section).

Figure 4B.35 shows an encoder termination panel.

Figure 4B.35

Encoder Termination Panel

AXIS

DRIVE

DRIVE
RET
SHLD

ENCODER

ENC POWER

CH A. HI
CH A. LO

AB SHLD

CH B. HI
CH B. LO

Z SHLD

CH Z. HI

CH Z. LO

EXT

POWER

+5V
RET

+15V

EX PWR OUT

SHLD

EX PWR IN
EX RET IN

FDBK IO

FDBK IO

RET

SHLD

91670401

1771HTE ENCODER TERMINATION PANEL

11305-I

4B.7

Encoder Termination Panel

Advertising