Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 510

Advertising
background image

Section 9A

Operator Interface

9A-43

Table 9A.V

HPG Fiber Optic Connectors

Connector On

Motherboard

Connected To

Remark

OP13 (RED)

Receiver on next module in I/O ring

Output

OP14 (BLACK)

Transmitter on previous module in I/O ring

Input

The HPGs require a +5V dc power supply. This is supplied from

connector BT03 on the operator panel power supply. If the control uses

more than three HPGs the system installer will have to provide an external

power supply. Table 9A.W lists the power requirements for the HPG.

Table 9A.W

HPG Power Requirements

Item

Specifications

Rated Input Voltage

5V dc

Power Source Voltage Range

4.75-5.25V dc

Power Consumption

Less than 0.4A

Connection

2-M3 Terminals

Distance from Power Supply

Less than 5 meters

Each HPG must have a unique node address on the I/O ring. The node

address corresponds to a unique address assigned to each HPG in the I/O

assignment file. Select the node address using the switch assembly shown

in Figure 9A.25. Table 9A.X lists the required switch assembly settings

for each possible node address.

Figure 9A.25

HPG Interface Board Switch Assembly Location

Bottom of HPG

Back of HPG

ON

1

2

3

11273-I

9A.5.2

HPG Power Requirements

9A.5.3

HPG Node Address Setting

Advertising