Section 4C

Connecting the 4-axis Servo Module

4C-26

Wiring Power for your Feedback Device (Analog Systems Only)

The control supports feedback devices with 5V compatible output signals.

The voltage that these feedback devices require may vary. The servo

module is equipped to supply 5V DC or 15V DC power to feedback

devices. These voltages may be accessed directly from the encoder

termination panel. However, for the 1394 this power connection is only

necessary if you are using optional feedback devices. The 1394 drive

supplies feedback power to the 1326 motor resolvers.

Important: Be aware that if the 5V DC encoder power is to be used the

connector P3 on the servo module must be directly connected to the power

supply. Refer to page 4D-4 for details on this power supply connection.

If your feedback device requires an external power supply, you can

incorporate it through the EXT. POWER connector on the termination panel.

Power outputs through the ENC POWER connector terminal labeled

EX PWR OUT. The next figure shows the termination panel connection for

EXT. POWER.

Figure 4C.18

Wiring Optional Customer Supplied Power Supply for Feedback Devices

Te

rm

Pa

ne

l

EXT.

POWER

EXT PWR IN
EXT RET IN

Optional

Customer Supplied

Power Supply

External Power

Ground

Shield

11308-I