10a.3.1 digital i/o connection, Power connection – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 542

Advertising
background image

I/O Interface

Section 10A

10A-19

Table 10A.K list the four types of digital I/O that can be selected according

to individual machine applications.

Table 10A.K

Digital I/O Types

Type

Power

Required

3

Input Points

4

Output Points

5

1

Color Code

E151

115/230 V ac

20@ 100/115 V ac

50-60HZ

2

10 Triacs: 85-265V ac

2 Relays: 10-250 V ac/

10-125V dc

RED

E152

115/230 V ac

20@ 200/230 V ac

50-60 Hz

2

10 Triacs: 85-265V ac

2 Relays: 10-250 V ac/

10-125V dc

BLacK

E153

115/230 V ac

20@ 24V dc

12 Relays: 10-250 V ac/

10-125V dc

BLUE

E154

24 V dc

20@ 24V dc

10 Transistors: 10-50 V dc

2 Relays: 10-250 V ac/

10-125V dc

GREEN

1

The color code appears in the upper right corner on the front of the unit.

2

10 Triac Outputs of sufficient capacity to energize size 0 - 3 contactors.

Two Isolated Relay Outputs.

3

Refer to table 10. M

4 Refer to table 10.N

5 Refer to tables 10.O-10.S

Power Connection

Figure 10A.13 and Figure 10A.14 show the power connection diagram for

the digital I/O.

Figure 10A.13

Power Connection (E151, E152, E153)

CHASSIS

GND

NOT

USED

230V ac

NEUT

115V ac

NEUT

115/230

V ac

Terminal

Block

Label

Terminal

Block

Label

CHASSIS

GND

NOT

USED

230V ac

NEUT

115V ac

NEUT

115/230

V ac

115V ac

L

H

To frame

To frame

L

H

230V ac

11318-I