Section 15B

Replacement Procedures

15B-38

3.

Loosen the four screws holding the battery pack to the control

chassis.

4.

Replace the old battery pack with a new one and tighten the four screws.

5.

Connect the new battery pack to connector CN10 on the 3-axis servo

module or connector P3 on the 4-axis servo module.

6.

Turn ON power to the control.

Batteries and battery replacement instructions are included with the battery

replacement kit. Before installing new batteries, use a voltage meter to

make sure that new battery voltage is higher than 3.5V.

The lithium battery contains heavy metals and

must be collected separately from other waste.

This is not available on the 9/230 control. To replace the digital servo

module:

1.

Turn OFF all power to the control.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

Important: The use of a ground strap is recommended to prevent static

discharge.

2.

Disconnect all cables that are connected to the servo module.

Important: The control must be “homed” after replacing the servo

module. If the servo motors incorporate an absolute encoder, the absolute

axis position will be lost. The absolute encoder must be reset after the

servo module is replaced. Refer to page 13A-33 for absolute encoder reset

procedures.

3.

Remove the 4 mounting screws that hold the board rack, which holds

the servo module to be replaced, in the component enclosure. Slide

the board rack out of the component enclosure board slot.

15B.23

Replacing the 3-axis

Digital Servo Module

Advertising