background image

Section 5B

9/440HR CNC/Drive System

5B-25

Wiring a Probe for Falling Edge Configuration

Figure 5B.12 shows a typical wiring diagram compatible with most probe

designs configured to trigger on the falling edge of the probe signal.

Figure 5B.12

Typical Wiring of a Touch Probe Configured for Falling Edge Trigger

11309-I

3
2
1

9/440HR Wiring Board

470 ohm

5V common

1000 ohm

+5 V dc

4

Probe Contact

to encoder interface