Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 236

Advertising
background image

Section 4D

Power Distribution and Wiring Guidelines

4D-6

Connecting the Main Power Supply to the Monochrome

Operator Panel Power Supply

You connect the operator panel power supply directly to the main power

supply. Refer to Figure 4D.2 and Figure 4D.4 when performing these steps:

1.

Use the ac power supply cable (C03) to connect terminals AUX-AC

L1 and L2 of terminal block BT04 on the main power supply to

terminals L1 and L2 of terminal block BT02 on the operator panel

power supply.

2.

Connect the chassis ground terminal on the operator panel power

supply to the cabinet’s grounding bus bar.

Important: The chassis ground terminal connects to the operator panel

chassis and designated cable shields. Power supply common is AC

coupled to chassis ground. It is the users responsibility to determine if a

direct connection to cabinet ground bus is required.

Figure 4D.4

Power Supply Connector on Monochrome Operator Panel

5 V

G N D

5 V

G N D

5 V

G N D

1 2 V

G N D

A C

T o H P G

T o H P G

T o H P G

T o M T B p a n e l
I/O m o d u le

19450

AC

L1

PE

HPG

GND

5V

5V

HPG

HPG

MTB

GND

GND

12V

GND

5V

BT02

L1

L2

L2

Advertising