Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 739

Advertising
background image

Section 15A

Troubleshooting the Control

15A-29

These columns are duplicated for INPUT and OUTPUT for each device.

The voltage values shown represent real time values with response limited

only by delays in screen updates.

Pressing the exit softkey (up arrow) at any time displays the Ring I/O

Menu screen.

If a 1394 Drive is selected on the Ring I/O screen and the {DISPLY}

softkey is pressed, the 1394 Drives Diagnostics screen appears.

Figure 15A.12 is an example of this screen. 1394 drives are discussed on

page 11A-1.

Important: This page only applies to 1394 drives that are present on the

9/Series fiber optic I/O ring. It does not apply to 9/440 CNC systems that

are integrated into the 1394 drive.

Figure 15A.12

1394 Drive Diagnostics Screen

1394 DRIVES
DEV NO.

00

AXIS MODULE FAULT
PWR

CRNT

VBUS

TEMP

SLOT 1

00

02

03

04

SLOT 2

05

06

07

08

SLOT 3

09

10

11

12

SLOT 4

13

14

15

16

SYSTEM MODULE FAULT
VHI

VLOW

GRND

TEMP

PHASE

17

18

19

20

21

Device Ring Address

Axis Module Faults

Axis Module Slot Number

System Module Faults

Note that the fault is active when the I/O number for that fault is shown in

reverse video. The following table lists the axis module and system

module faults and gives a description.

15A.4.9

1394 Drives

Diagnostics Screen

Advertising