Section 8

Communication Interface

8-20

into the 9/Series remote I/O connection. These values are then stored on

the control where they are assigned to the remote I/O input PAL flags

($RMI1-$RMI8).

When sending data from the control to a PLC processor, PAL must first

assign values to the remote output flags ($RMO1-$RMO8). The control

passes these output flag values to the PLC processor where they are loaded

into eight input words in the PLC input image table.

Figure 8.14 shows the remote I/O module as it comes mounted to the
component enclosure for 9/290 controls.

Figure 8.14

Remote I/O Module Mounted to the Component Enclosure

Remote I/O Module

(9/290 only)

Mounting the Remote I/O Module to the Component Enclosure

If you ordered the remote I/O module with your 9/290 control, it comes

already assembled and mounted to the component enclosure. If you have

ordered the remote I/O module separately, use this procedure to mount the

remote I/O module to the component enclosure:

1.

Remove the parts from the bag

8.9.1

9/290 Remote I/O Module