Error and System Messages

Section 16

16-12

Message

Description

DRESSER MIS-POSITIONED

Wheel re-enable was requested with IPD active and wheel is more than 4 inch-programming

counts (hard-code amount) away from its previously active absolute position. Wheel dressing

does not start.

DRESSER NOT INITIALIZED

This error is generated if an attempt is made to activate the in--process dresser before the

dresser has been initialized through a wheel calibration operation.

DRESSER NOT/MIS CONFIGURED

The grinder over-the-wheel dresser feature issues this message when a wheel is initialized and

the dresser parameters in AMP have been misconfigured. This message is issued when the

dresser axis, dresser vertical axis, or dresser other axis has not been selected, or has been

AMPed to have common axes, or has been AMPed to be a non-existent axis name.

DRESSER WARNING LIMIT REACHED

The axis specified as the dresser axis has been dressed smaller than the dresser warning limit

value as specified on the dresser status page.

DRILL AXIS CONFIGURATION ERROR

The drilling axis is not a currently configured machine axis. On dual processing controls this

message may result when the drilling axis is in another process. The drilling axis must be a

configured axis in the current process and should not be the slave of a dual axis (drill axis

should be the master axis for dual group). On machines with dual axes, this message can

mean the axis configured in AMP as the fixed-drilling axis is a slave axis. The drill axis should

be the master axis.

DUAL AXES MASTER&SLAVE PROCESS NOT SAME

When configuring a dual axis on a dual processing system, configure AMP so all axes in the

dual axis group are in the same source process even if the dual axis group is shared.

DUAL AXES PARK LOGIC CANNOT CHANGE

An attempt was made, using dual axes, to change the current park status. At this point, the

request will not be allowed.

DUAL GROUP AXES MUST HAVE SAME ROLLOVER

All rotary axes in a dual axes group must have the same rollover value. These rollover values

are set in AMP.

DUAL LATHE-MUST USE PROCESS 1,2

Dual lathe must have the active processes be the first 2 available in AMP; 3 or 4 should not be

configured as an active process.

DUAL MASTER&SLAVE RAD/DIAM CONFIG ERR

The slave of a dual group has been defined as a diameter axis. The OEM must define the

master to be a diameter axis and the system will change the slave to be a diameter axis. When

the group is decoupled the slave will continue to take on the master’s rad/diam traits.

DUAL PLANE CONFIGURATION ERROR

In AMP you have defined a plane with an axis and a master and a slave in the wrong order. For

example: If the system has 4 axes YXZU and ZU are duals, if an AMPed plane is ZX, then UX

can not be and AMPed plane. It must be XU (refer to your AMP reference manual for details).

DUAL SLAVE OR SPLIT AXIS NOT ALLOWED

Neither a dual slave, nor a split axis (deskew axis) may be programmed in a G24, G25, or G26

block.

DUALS CANNOT CHANGE OFFSETS IN CIRCULAR

An attempt was made, using dual axes, to account for an offset change in a circular move.

Dual offset changes can only be made in linear blocks.

DUALS ONLY ALLOWING SINGLE AXIS HOME

An attempt was made to home multiple axes in a dual group when PAL only allows one axis at a

time to be homed. PAL can be changed to allow homing of multiple axes in a dual group.

DUALPORT PTO TEST FAILED

The Dualport failed the diagnostic test and the bootstrapping operation is skipped. Consult

Allen-Bradley customer support services.

DUPLICATE 1394 SLOT

The 1394 rack ID and slot number AMP entries are the same for two or more servos. Each axis

module in a 1394 rack must have an individual address.

DUPLICATE 7300 PATTERN NAME

An attempt was made to enter a 7300 pattern name that already exists.

DUPLICATE DUAL MASTER NAMES

Both dual master axes names have the same letter.

DUPLICATE I/O RING DEVICE

Two or more of the same type of device on the I/O ring have the same device address switch

setting.

DUPLICATE PROGRAM

An attempt was made to rename a program in control memory using the same program name

(or number) of another program already in memory.

DUPLICATE PROGRAM NAME

An attempt was made to store or copy a program in control memory using the same program

name (or number) of another program already in memory.