Error and System Messages

Section 16

16-37

Message

Description

REMOTE I/O MISSING USER OPERATIONAL CODE

The RIO module did not detect the user operational code after reset. This fault is displayed

when the RIO module does not detect the user operational code in the user status register in

common RAM within 100ms after the RIO module has set its operational code and released

control of common RAM back to the user device. The Interboard Communications Fault LED is

turned ON.

REMOTE I/O RIO DENIED COMMON RAM ACCESS

The RIO module was denied access to CRAM for longer than the specified interval. The RIO

module failed to gain access to common RAM after attempting for the Accessing Time-out time

period. The time-out is due to either the user device maintaining access for more than the

Accessing Time-out interval. or to a hardware failure. The Interboard Communications Fault

LED is turned ON.

REMOTE I/O SERIAL COMMUNICATIONS FAULT

The RIO module cannot communicate with the PLC processor. Either the PLC processor’s

power is OFF, the blue hose is not connected, or the PLC processor is in Edit mode.

REMOTE I/O SIO CHIP TEST FAULT

The RIO module tests the SIO chip after reset and detects a fault. The processor fault LED is

turned ON.

REMOTE I/O UNABLE TO FIND BT DATA BUFFER

The RIO module was unable to detect the user block transfer data buffer. The interboard

communications fault LED is turned ON.

REMOTE I/O UNRECOVERABLE ERROR

Remote I/O hardware or network has catastrophic failure. Cycle power to try to restart or check

remote I/O hardware (9/920 only).

REMOTE I/O USER FAULT OCCURRED

The RIO module detected that the user fault bit was set. The interboard communications fault

LED is flashing.

REMOTE I/O WATCHDOG TIMEOUT

The watchdog mechanism on the RIO module timed out, indicating that the RIO module has not

operated in an expected manner for possibly 17ms. The processor fault LED is turned ON.

REMOTE IO INTERPROCESSOR HANDSHAKE FAULT

The RIO module failed to detect the complement of the user-handshake word, in the

complement user-handshake word in common RAM, within the handshake interval. The user

device has not shook hands with the RIO module. The interboard communications fault LED is

flashing.

REPLACE ABSOLUTE FB BATTERY

The battery that attaches to the servo module and supplies power for the absolute encoders is

under-voltage and must be replaced.

REPLACE MEMORY BACKUP BATTERY

The battery that attaches to the main processor board and supplies power for the control’s RAM

memory is under-voltage and must be replaced. If not replaced, AMP data cannot be copied to

backup memory and part program data may be lost.

REQUESTED DATA TOO LARGE

The data you are trying to send or receive is too large.

REQUIRES AT LEAST TWO AXES

A transfer line quick view prompt was selected for a cycle which requires two or more axes.

Your system is currently configured as a single axis system.

RESETTING E--STOP

Once you push the E--Stop Reset button to clear the E--Stop state, the Resetting E--Stop

message displays to alert you that the control is attempting to come out of E--Stop. After the

system is out of E--Stop and the drives are enabled, the control clears this message. If the error

condition is not cleared, this message clears, but the “E--STOP”message continues to flash as

the control remains in E--Stop state.

RETRACE NOT ALLOWED

A retrace is not allowed from the point in program execution.

RIGHT OPERAND MUST BE POSITIVE

The right operand of a logical operator must be a positive value. Negative values are illegal; for

example, 1AND--2 is illegal because of the --2.

RING I/O RECOVERY DISABLED

This message is activated when the {RECVRY DISABL} softkey is pressed on the I/O RING

MONITOR page. It is a visual indicator that the operator has disabled the I/O Ring retry

functionality.

RIO COMMON RAM ACCESS NOT ACKNOWLEDGED

The control’s request to use the RIO module was denied. The RIO module lost power, or the

control was restarted, but the RIO module was not.

ROLLOVER/OVERTRAVEL INCOMPATIBLE

Overtravel limits were specified in AMP for an axis that is configured as a rollover axis. Rollover

axes do not have overtravel limits.

ROTARY AXIS CANNOT BE SCALED

A rotary axis cannot be scaled.