9a.2.4 mounted operator panel node address setting – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 477

Advertising
background image

Section 9A

Operator Interface

9A-10

Each operator panel must have a unique node address on the I/O ring. The

node address corresponds to a unique address assigned to each operator

panel in the I/O assignment file. The node address is selected by cutting

the jumpers located on the operator panel. Figure 9A.7 shows the location

of the jumpers on the operator panel.

Figure 9A.7

Operator Panel Jumper Location

5V

GND

5V

GND

5V

GND

GND

AC

To HPG

To HPG

To HPG

To MTB panel

I/O module

12V

JP1

JP2

Rear

Front

Operator

Panel

BT02

L1
L2

PE

The preceding figure shows the jumpers located on the keyboard I/O ring

interface board of the the monochrome operator panel. This board is also

used by the color and color flat panel operator panels. Locate this board by

the fiber optic connections.

9A.2.4

Mounted Operator Panel

Node Address Setting

Advertising