Section 15B

Replacement Procedures

15B-57

5.

Remove the four ROP module mounting screws.

6.

Install the jumper on jumper J1 across pins 1 and 2 on the new

8520-ROP.

7.

Installation of the new ROP module is the reverse of steps 1 to 5.

To replace the either the CRT or the keyboard assembly in the removable

operator panel follow these procedures:

1.

Make sure power to the removable operator panel has been

disconnected.

2.

Open the front and back cover of the removable operator panel.

3.

Remove the front and back cover by sliding the cover off its hinge

pins. Do this by firmly pushing the cover to the left while it is open.

4.

Disconnect the 37--pin D--shell removable operator panel interface

cable (CN4) from the ROP interface module.

5.

Remove the eight screws that hold the operator panel in the

removable panel case from the front of the unit.

6.

Slide the operator panel assembly out the front of the case.

7.

Follow the monochrome CRT replacement procedure from page

15B-25 or the keyboard replacement procedure from page 15B-26.

15B.39

Replacing the Removable

Operator Panel CRT or

Keyboard Assemblies