10a.3 digital i/o – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 541

Advertising
background image

I/O Interface

Section 10A

10A-18

The Digital I/O provides for an additional 20 inputs and 12 outputs to the

system I/O ring. The digital I/O interface circuits are designed to interface

this I/O device with the fiber optic I/O ring. These circuits use a fiber

optic transmitter and receiver to provide communication with the fiber

optic I/O ring.

The digital I/O receives input signals from external devices assigned to its

input terminals. These signals are sent to PAL, through the I/O ring, to be

used in the ladder logic process. PAL generates signals that are then sent

through the I/O ring to the digital I/O. The digital I/O outputs these signals

to external devices assigned to its output terminals.

This section covers the specifications, connection and the settings for the

digital I/O. Figure 10A.12 shows the digital I/O.

Figure 10A.12

Digital I/O

Fuse

Color code location

Optical connector

OUT (OP21)

Optical connector

IN (OP22)

11317-I

There are four types of digital I/O. The four types have different

combinations of power supply and I/O specifications.

10A.3

Digital I/O

Advertising