9/440 resolver--based power strip – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 280

Advertising
background image

Section 5A

9/440 Resolver--based CNC/Drive System

5A-34

Figure 5A.18

Recommended Connection of 3- phase Drive Power

Customer Supplied

E--Stop Control Relay

DC+

INT

COL

W1

W2

U

W

V

PE

9/440 Resolver--based Power Strip

E--Stop

Connector TB1

1

7

E--Stop

status contact

(30V dc 1.4A)

Noise suppressor

Customer supplied

24V Power Supply

Output 24 V ac or

24 V dc

AC Bulletin 100--A30N x 3 (surge protector required) or

DC Bulletin 100--A30NZ x 3

Bussman FRS--R--20A (class RK-5)

600 V AC (qty 3)

Three-phase input

360 or 480V AC

Bulletin 100

Contactor Power

Noise suppressor

Other Customer Controlled

E--Stop Status Relays

Customer

Supplied

Fuse

c

c1

m

m1

m2

m3

Advertising