Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 456

Section 8
Communication Interface
8-23
Figure 8.16 shows the remote I/O module as it comes mounted in the
component enclosure for 9/260 controls.
Figure 8.16
Remote I/O Module Mounted in the Component Enclosure
Remote I/O
Communication Module
CPU
Module
Enclosure
19441
Mounting the Remote I/O Module in the Component Enclosure
If you ordered the remote I/O module with your 9/260 control, it comes
already mounted in the component enclosure. If you have ordered the
remote I/O module separately, use this procedure to mount the remote I/O
module in the component enclosure.
Important: You can not use the remote I/O module in a 9/260 system that
contains either a 9/Series Data Highway Plus communication module or a
9/Series MMS/Ethernet communication module. A 9/260 system can
contain only one Remote I/O, DH+, or MMS/Ethernet module.
ATTENTION: To prevent damage to the module, wear an ESD
wristband while you unpack and install the module. Connect the
wristband to the ground screw on the control’s component
enclosure.
8.9.2
9/260 Remote I/O Module