Error and status messages – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 763

Advertising
background image

Section 15B

Replacement Procedures

15B-7

10. When you press a key, the update procedure begins again at step 6.

Error and Status Messages

As you use the update utility, the control and your PC display status and

when necessary, error messages. The status messages tell you what the

control is doing or what it has just done. The utility displays error

messages when it cannot complete the update. Table 16.A lists the error

messages and recovery steps.

Table 16.A

Error Messages and Recovery Steps for the Update Utility

Messages that Appear on the PC Screen

Message

Recovery

Boot directory conflict

Call Allen-Bradley Support Services.

Communication line error detected

Retry at lower baud rate. If that does not work check communication ports and connections.

Check config.sys file for proper device driver setup.

Connected to invalid device

Make sure you are connected to a 9/230, 9/260, 9/290, or 9/440, and not a 9/240.

Could not open DF1 protocol on COM1

Retry at lower baud rate. If that does not work check communication ports and connections.

I/O error on file

Check disks to make sure that they have not been damaged.

Module has an invalid checksum

Check disks, communication connections, and flash SIMMs.

Retry update.

Not enough RAM available

Add memory to your PC.

System update files are corrupt

Call Allen-Bradley and request a new update utility.

Unable to connect to control

Retry at lower baud rate. If that does not work check communication ports and connections.

Check config.sys file for proper device driver setup.

Unable to download

Refer to recovery for the error message on the next line of the display.

Unable to find file

Check the disk in the external drive. Make sure it is an update disk.

Unable to open file

Check the disk in the external drive. Make sure it is an update disk.

Unable to set up communications port

Retry at lower baud rate. If that does not work check communication ports and connections.

Update floppies corrupt: Inconsistent

module revision

Call Allen-Bradley and request a new update utility.

Messages that Appear on the Control Screen

Message

Recovery

Boot directory is missing

Retry update.

Comm error while processing host

request

Retry at lower baud rate. If that does not work check communication ports and connections.

Flash SIMMs are not installed

Install the flash SIMMs onto the CPU board (for 9/260 or 9/290) processor board (9/230).

Flash SIMMs contain invalid data

Retry update.

Flash SIMMs U10 and U14 are empty or

missing

Make sure your flash SIMMs are installed in the correct tracks.

Flash SIMM U10 is empty or missing

Make sure your flash SIMMs are installed in the correct tracks.

Advertising