Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 415

Advertising
background image

Section 7B

Fiber Optic Connections

7B-3

Table 7B.A shows the specifications for the fiber optic cable used to

connect optical transmitters to optical receivers. Table 7B.B shows the

fiber optic thermal Specifications and Table 7B.C shows the cable

attenuation specifications.

Table 7B.A

Fiber Optic Cable Mechanical Specifications

Fiber Optic Mechanical Specifications

Min

Max

Units

Cable Length

-

27

m

Tensile Load During Installation

-

30

Kg/Cable

Tensile Load in Continuous Use

-

30

Kg/Cable

Bend Radius

50

-

mm

Impact (10mm R 1/2 cyl. of 1Kg mass)

-

5

cm

Twisting

-

5

Twists/m

Table 7B.B

Fiber Optic Cable Thermal Specifications

Fiber Optic Thermal

Specifications

Min

Max

Units

Storage Temperature

-40

+85

°

C

Application Temperature

0

+70

°

C

Table 7B.C

Fiber Optic Cable Attenuation Specifications

Fiber Optic Attenuation Specifications

Min

Max

Units

30 meter (conditions: 660 nm, 25

°

C)

.21

.30

dB/meter

10 meter (conditions: 660 nm, 25

°

C)

.23

.34

dB/meter

Advertising