Section 15A

Troubleshooting The Control

15A-26

If an Operator Panel Keyboard (OPERATOR PANEL) device is selected

on the Ring I/O screen and the {DISPLY} softkey is pressed, the Operator

Panel Keyboard (OPERATOR PANEL) Diagnostics screen appears.

Figure 15A.9 is an example of this screen.

Figure 15A.9

OPERATOR PANEL Diagnostics Screen

OPERATOR PANEL

SETUP MODE

DEVICE NO.

NUMBER

0

1011000

X

The device numbers of all operator panel devices that are on the I/O Ring

will appear under the “OPERATOR PANEL” heading. These may be any

decimal numbers from 0 to 3.

To the right of the device number is a number that represents the binary

output from each of the operator panel keys. This number changes as the

operator panel keys are depressed. The symbol of the key that is depressed

will be displayed to the right of this number.

To verify key actuation, place a volt meter or oscilloscope probes between

test points TP1 (GND) and TP2 (KEY_ON) located on the keyboard

interface module. A logic high or +5V dc measured between TP1 and TP2

indicates a key actuation.