Section 5A

9/440 Resolver--based CNC/Drive System

5A-42

System Grounding

Figure 5A.21 illustrates the recommended 9/440 Resolver--based

grounding scheme. All grounds terminate on a single point. Note there are

two separate ground wires going to the system module. One ground

connects to PE of the system module power terminal block, the other

connects to the ground stud found just beneath the wiring board on the

mounting bracket for the 9/440 Resolver--based CNC assembly.

9/440 Resolver--based

System Module

Open

cover

9/440

Resolver--based CNC

Assembly

PE Stud

Power Terminal Block

DC+

INT

COL

W1

W2

U

W

V

PE

PE Power Terminal Block Ground