background image

I/O Interface

Section 10A

10A-20

Figure 10A.14

Power Connection (E154)

Terminal

Block

Label

To frame

24 V dc

CHASSIS

GND

NOT

USED

NOT

USED

24V dc

NEUT

+24

V dc

11319-I

ATTENTION: Incorrect wiring can cause damage to the digital

I/O power supply. Do not jumper the 115V ac NEUT and the

230 V ac NEUT together. Do not jumper the 115V ac NEUT or

the unused 230V ac to the Chassis GND terminal.

Input Device Connection

Table 10A.L lists the terminals of the digital I/O input terminal strips. You

can assign an input device to each terminal. Use the blank space beside

each terminal number to indicate any terminal assignments that are made.

The terminal assignments will have to correspond to the terminal

assignments of the digital I/O in the PAL I/O Assignment file. The I/O

assignment file will have to be edited if the terminal assignments do not

correspond. Refer to the 9/Series CNC 9/230, 9/260, and 9/290 PAL

Reference Manual, publication 8520-4.3, for more information.