Section 13A

Connecting 8520 Digital Drive Systems

13A-12

Table 13A.A

Formulas for Determining Transformer Size

If you are using a machine tool application with:

Use this formula to calculate the minimum transformer

KVA

Varying loads on the motor

Number of Axes

Machine Tool Duty

(Machine Tool Duty)

1

KW (Largest Motor) x 0.43 + 0.2

2

KW (Largest Motor) x 0.61 + 0.4

3

KW (Largest Motor) x 0.86 + 0.6

4

KW (Largest Motor) x 1.28 + 0.8

5

KW (Largest Motor) x 1.82 + 1.0

6

KW (Largest Motor) x 2.60 + 1.2

Constant acceleration and deceleration

Number of Axes

Rapid Accel/Decel Duty

(Rapid Accel/Decel Duty)

1

KW (Largest Motor) x 0.60 + 0.2

2

KW (Largest Motor) x 0.85 + 0.4

3

KW (Largest Motor) x 1.20 + 0.6

4

KW (Largest Motor) x 1.80 + 0.8

5

KW (Largest Motor) x 2.50 + 1.0

6

KW (Largest Motor) x 3.50 + 1.2

Motors that perform continuously at or near peak capacity

Number of Axes

Continuous Duty

(Continuous Duty)

All

KW (Total of All Motors) x 1.2 + 1.0

If you are using 8520 digital servo amplifiers, select a transformer from

this list of Allen-Bradley 1389 transformers. Base your selection on the

calculated minimum transformer KVA rating such that the selected

transformer’s KVA rating is equal to or larger than the calculated value:

Catalog Number

Rating (KVA) Primary Voltage and Frequency

1389-T015DA

1.5

240/480V ac, 3

f

60Hz

1389-T035DA

3.5

1389-T050DA

5.0

1389-T100DA

10.0

1389-T125DA

12.5

1391-TA2

NEMA 1 Transformer Enclosure

The dimensions of the Allen-Bradley 1389 transformers are shown in

Figure 13A.8 and Figure 13A.9.