Section 5B

9/440HR CNC/Drive System

5B-31

Logic power should be wired so that if the 24 V is not available to the

system module, it will open the drive contactors and disable 3 phase drive

power (see Figure 5B.20).

Figure 5B.17

Connecting On/Off Power Control Assembly and 24V Transformer

ON SW

COMMON

OFF SW

AC IN

AUX AC

AC POWER

FUSE

8A/250V

ALLEN--BRADLEY

Customer supplied

24V transformer

Input 85-265 V ac

Output 24 V ac or

24 V dc non-polarized

ON

COM

OFF

E-STOP

COM

RESET

MTB Panel

Incoming Power

85--265 V ac

DC+

INT

COL

W1

W2

U

W

V

PE

9/440HR Power Strip

PE

ON/OFF

Control Assembly

BT02

Monochrome or Color

operator panel power

supply

To local cabinet

ground bus

High

Low

Noise suppressor

4 amp max draw

15 AMP

Customer Supplied

Fuses

L2

L1

PE

L2

L1

ATTENTION: You must make sure logic power (24V) is

applied to the system module and the system module is out of

E-STOP before you allow 3 phase power to be enabled.