Section 5B

9/440HR CNC/Drive System

5B-36

See page 5B-12 for details on high--resolution feedback device cables

(1326-CECU--x).

1326AB servo motors have integral thermal protection. This contact must

be connected in the E-STOP string for motor overload protection.

Connections are performed through the front panel terminal block as

shown in Figure 5B.21. Refer to the information below and the

Interconnect Drawings on page 5B-40 for further information.

Table 5B.B

Motor Power Terminations

Terminal

Description

Wire/Pin Number

U1

Motor Power A

1

V1

Motor Power B

2

W1

Motor Power C

3

PE1

Axis Ground

Ground Bar

PE2

Motor Ground

8

PE3

Overall Shield

7

Thermal and Brake Leads
The motor thermal sensor and brake leads (if used) are connected to the

Axis Module at TB1 & TB2. See Figure 5B.21 for location and

Table 5B.C for terminations.