5b.5 power terminal block connection – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 319

Advertising
background image

Section 5B

9/440HR CNC/Drive System

5B-29

All external power connections to the 9/440HR CNC/Drive are wired
through the system modules power strip, located behind the front cover in

the lower right corner. Input power is wired to this strip in two different

voltages:

24 V Logic Power -- this is 24 V AC or 24 V DC. The logic power is
used to operate the processors in the system module, axis module logic

boards, and power the encoders.

Drive Power -- this is 324-528 V AC, three phase, 50/60 Hz. The drive
power is used to supply the drive portion of the 9/440HR the voltages

necessary to power the axis modules and the servo motors.

To this Power

Strip Connector

Connect:

W1

+24 V Logic Power

W2

24 V Logic Power common

U, V, W

380/460V AC, three--phase power

(not phase sensitive)

PE

System Ground Bar

DC+, INT, COL

Shunt resistor connection. When the jumper exists between INT

and COL the internal 200 W shunt is used. When using the

optionally purchased 1000 W shunt the jumper is removed and

the new shunt is installed between DC+ and COL.

All connectors on the power strip support a maximum of AWG 12 gauge solid wire.

9/440HR System Module

Wiring Board

E-Stop connections

(TB1)

Power Terminal Block

DC+

INT

COL

W1

W2

U

W

V

PE

5B.5

Power Terminal Block

Connection

Advertising