Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 563

I/O Interface
Section 10A
10A-40
Figure 10A.31 shows the output circuit diagram for the high--density I/O
module.
Figure 10A.31
High- density I/O Module Output Circuit Diagram
High--density I/O Module
Signal destination
Load
PE
Com.
+24V
11336-I
BT33
TB2
BT33
TB2
CN63F
Customer--supplied
dc power supply
Table 10A.AC lists the connectors used to make the fiber optic
connections to the I/O ring. Each module connected to the system I/O ring
has an optical transmitter and receiver. Fiber optic cables connect
transmitters to receivers to form the I/O ring. Refer to Appendix A for
additional information on fiber optic cables and connectors.
Table 10A.AC
High- density I/O Module Fiber Optic Connectors
Connector on Digital I/O
Connected To
Remark
OP23 (RED)
Receiver on next module in I/O ring
Output
OP24 (BLACK)
Transmitter on previous module in I/O ring
Input
10A.4.3
High- density I/O Module
Fiber Optic Connection