7a.2 cable diagrams – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 361
![background image](/manuals/580751/361/background.png)
Section 7A
Connecting Components
7A-13
The cables and connectors shown in the previous figures are covered in the
following table. For detailed information on a specific connector, refer to
the section that covers the module on which the connector is located.
ATTENTION: Incorrect wiring of the following cables and
connectors may cause damage to their respective modules.
Table 7A.A
Cable and Connector List
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C01
9/230
Main Power Supply BT04
ON/OFF Switch Signal Cable
MTB Panel BT20
Prepared by Customer
19419
ON
SW
COM
OFF
SW
24V dc
24V dc
RTRN
L1
ac
IN
L2
PE
L1
L2
AUX
ac
ON
COM
OFF
E-Stop
COM
RESET
Power Supply
MTB Panel
C01
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
Miscellaneous
Belden 9491
Miscellaneous
Line Drop Limit
7A.2
Cable Diagrams