background image

I/O Interface

Section 10A

10A-24

Figure 10A.18 shows a relay type output connection diagram.

Figure 10A.18

Relay Type Output Connection (E153)

Relay type output

Relay type output

Relay output - Group 1

V ac/V dc Common

Relay output - Group 2

Solenoid

M

M

Incorporated

noise

suppressor

230 V ac

115 V ac

dc

dc +

dc -

L1 (H)

L2 (L)

L1 (H)

L2 (L)

Customer supplied

Customer supplied

Customer supplied

Noise

suppressor

Noise

suppressor or

load resistor

Noise

suppressor or

load resistor

A12

A13

A14

A15

A16

B12

B13

B14

B15

B16

B11

A11

V ac

V dc

V ac

V dc

NOT

USED

NOT

USED

11323-I

V ac/V dc Common

Important: The relay type output circuits of Group 1 (A12 - A16) and

Group 2 (B12 - B16) incorporate a noise suppressor.

Important: Surge suppression reduces arcing of an output contact and is

recommended for most applications, particularly when switching an

inductive load off.

Relay contacts A11 and B11 do not have built-in suppression and may

exhibit 50% of the relay life of contacts A12-A16 and B12-B16.

The contact life of relays used in the output circuits of the E153 module

can be significantly reduced if surge suppression is not connected across

the load. Performance testing indicates that contact life may be reduced by

as much as 30% without surge suppression across the load.