Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 799

Advertising
background image

Section 15B

Replacement Procedures

15B-43

5.

Remove the screws that secure the logic board(s) to the servo

amplifier chassis.

6.

Carefully push the wires and connectors to the side and remove the

logic board(s).

7.

Install the logic board(s) onto the new servo amplifier power section

by reversing the removal procedure. First position the board(s) on

the chassis and verify that all wires and connectors are accessible.

8.

Install and tighten the screws that secure the logic board(s) to the

chassis.

9.

Reconnect all wires and connectors to the logic board(s) as labeled,

including the chassis ground wire.

10. Return the servo amplifier to the cabinet and reconnect it.

11. Turn ON power to the control and servo amplifier.

This is not available on the 9/230 control. To replace the optional feedback

module:

1.

Turn OFF all power to the control.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

2.

Remove the servo module next to the optional feedback module.

3.

Disconnect all cables connected to the optional feedback module.

4.

Disconnect the optional feedback module from the servo module.

5.

Replace the optional feedback module with a new one.

6.

Set jumper JP1 on the new optional feedback module to correspond

to the setting of jumper JP1 on the old optional feedback module.

7.

Adjust the variable resistors (pots) on the new optional feedback

module so they to correspond to the settings of the variable resistors

(pots) on the old optional feedback module.

8.

Reconnect all cables that were disconnected.

15B.27

Replacing the Optional

Feedback Module