ANALOG OUT (TB2) Auxiliary Output Connector.

An auxiliary analog output is provided through the connector labeled

ANALOG OUT (TB2). This connector is typically used to command an

analog spindle drive system with no position feedback. TB2 is not capable

of receiving encoder feedback information. Figure 4B.31 shows the

location of ANALOG OUT connector and lists terminal assignments of

this connector.

Important: Note that TB2 should only be used for drive applications that do

not require a feedback device. If a feedback is required, the output signal to

the drive and its corresponding encoder feedback should be wired through

one of the axis connectors J1, J2, or J3. A drive application with feedback

would typically not use the connector labeled ANALOG OUT (TB2).

However, if necessary, TB2 may be used with encoder feedback configured in

AMP to be returned to one of the axis connectors J1, J2, or J3.

Figure 4B.31

Terminal Block ANALOG OUT, 3 Plug-type Terminal Block Connections.

Terminal

No.

Signal

Description

Signal Destination

1

Analog Out

+

±

10V Analog with no

feedback

(typically spindle drive)

2

Analog Out

-

Signal Return

(typically spindle drive)

3

Shield

shield

connect at module only