Section 15A

Troubleshooting The Control

15A-2

This section describes the operation of a software utility supplied with your

9/Series ODS disks. This utility allows you to initialize the control to

Default AMP parameters and /or remove the PAL logic program.

Use of this utility may become necessary if during power turn on (PTO)

the CRT is blank and system watch-dog LED is not on, or if the PTO

screen is displayed with no error messages and pressing “transmit” does

not change the display. For example you may need to use this utility when

a PAL program downloaded to the control requires a foreground scan time

that is incompatible with the AMP defined “system scan time” parameter.

This initialization utility is not activated in the same way that other ODS

functions are called (pull-down menus). It must be converted from the

compacted form as it is stored on the original ODS floppies to the hard

disk of the workstation (PC).

1.

Create a directory to be used for this utility, and “CHANGE

DIRECTORY” to this directory. For example:

MKDIR TEMP

makes the directory called temp.

CD TEMP

changes to the temp directory.

2.

Depending on the floppy disk size you are using, copy one of the files

listed below from the original ODS disk to the new directory (TEMP

in our example):

- INIT33.ZIP

from the 3 1/2 inch disk #3

- For example:

COPY B:INIT33.ZIP C:\TEMP

copies the init33.zip file from the B: drive to

the temp directory on the C: drive

3.

While in the newly created directory (temp in our example),

uncompress the Initialize utility using PKUNZIP. PKUNZIP is found

on disk #1 of your ODS disks. Place disk #1 in the disk drive and

enter the appropriate command based on which “INIT...” file was

copied. For example:

B:PKUNZIP INIT33.ZIP

uncompresses the initialize utility

The initialize utility is now ready to use.