I/O Interface

Section 10A

10A-46

Figure 10A.36

E- Series Analog I/O Output Device Connection

CHASSIS

GND

COM

OUTPUT

CHASSIS

GND

NOT

USED

NOT

USED

NOT

USED

NOT

USED

CHASSIS

GND

CHASSIS

GND

CHASSIS

GND

Terminal

Block

Label

Shielded cable

To analog device

11341-I

Table 10A.AH lists the analog I/O connectors used to make the fiber optic

connections to the I/O ring. Each module connected to the system I/O ring

has an optical transmitter and receiver. Fiber optic cables connect

transmitters to receivers to form the I/O ring. Refer to Appendix A for

additional information on fiber optic cables and connectors.

Table 10A.AH

E- Series Analog I/O Fiber Optic Connectors

Connector on Digital I/O

Connected To

Remark

OP25 (RED)

Receiver on next module in I/O ring

Output

OP26 (BLacK)

Transmitter on previous module in I/O ring

Input

Different types of I/O devices can have the same node address, but devices

of the same type must each have a unique node address. Each analog I/O

is assigned a unique node address in the I/O assignment file of ODS. This

address corresponds to a switch setting on the analog I/O device.

Figure 10A.37 shows the location of the node address switch assembly on

the analog I/O.

10A.5.3

E- Series Analog I/O Fiber

Optic Connection

10A.5.4

E- Series Analog I/O Node

Address Setting