background image

Section 5A

9/440 Resolver--based CNC/Drive System

5A-24

Wiring a Probe for Falling Edge Configuration

Figure 5A.10 shows a typical wiring diagram compatible with most probe

designs configured to trigger on the falling edge of the probe signal.

Figure 5A.10

Typical Wiring of a Touch Probe Configured for Falling Edge Trigger

11309-I

3
2
1

9/440 Resolver--based Control

Wiring Board

470 ohm

5V common

1000 ohm

+5 V dc

4

Probe Contact

to encoder interface

Advertising