10a.4 high- density i/o module – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 556

Advertising
background image

I/O Interface

Section 10A

10A-33

Table 10A.V

Digital I/O Node Address Setting

Node Address

Switch Assembly Position

Hexadecimal

Binary

1

2

3

4

5

6

00

00 0000

OFF

OFF

OFF

OFF

OFF

OFF

01

00 0001

OFF

OFF

OFF

OFF

OFF

ON

02

00 0010

OFF

OFF

OFF

OFF

ON

OFF

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

3D

11 1101

ON

ON

ON

ON

OFF

ON

3E

11 1110

ON

ON

ON

ON

ON

OFF

3F

11 1111

ON

ON

ON

ON

ON

ON

The high--density I/O module provides for an additional 66 inputs and 36

outputs to the system I/O ring.

The high--density I/O module receives input signals from external devices

assigned to its input terminals. These signals are sent to PAL, through the

I/O ring, to be used in the ladder logic process. PAL generates signals that

are then sent through the I/O ring to the high--density I/O module. The

high--density I/O module outputs these signals to external devices assigned

to its output terminals.

This section covers the specifications, connection and the settings of the

high--density I/O module (cat. nos. 8500-HDM).

10A.4

High- density I/O Module

Advertising