Section 15B

Replacement Procedures

15B-42

9.

MATCH JUMPERS on the new servo amplifier logic board(s) to the

settings on the board(s) being replaced. Amplifier jumper settings are

listed starting on page 13A-16.

ATTENTION: Jumper settings configure the amplifier to

match the specific application. Failure to match jumper settings

on the new servo amplifier may result in damage to the

amplifier, servomotors, or machine.

10. Turn ON power to the control and servo amplifier.

The servo amplifier power section includes the entire servo amplifier

chassis and all components mounted beneath the servo amplifier logic

board. Replacement requires removal of the servo amplifier from the

cabinet.

To replace the servo amplifier power section on a servo amplifier:

1.

Turn OFF all power to the control and the servo amplifier.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open (off) and

locked.

Important: The use of a ground strap is recommended to prevent static

discharge to any of the sensitive electronic components on the servo

amplifier logic board(s).

2.

Remove the servo amplifier from the cabinet as discussed earlier in

this section.

3.

Carefully label and disconnect all wires and connectors to the logic

board(s).

Important: Labeling is essential since some connectors are the same size

and could be accidentally interchanged.

4.

Disconnect the chassis ground wire from the logic board(s). If the

ground wire is soldered to the logic board, it will have to be

disconnected at the chassis, just to the left of TB1.

15B.26

Replacing the Power

Section on the Digital Servo

Amplifier

Advertising