Section 4D

Power Distribution and Wiring Guidelines

4D-8

Connecting Main Power Supply to the Color Operator Panel

You connect the operator panel power supply directly to the main power

supply. The operator panel power supply receives power from the color

CRT power supply through an internal jumper from the AC (L1 and L2)

terminals.

Figure 4D.6

Color Operator Panel Power Supply Connection

5 V

G N D

5 V

G N D

5 V

G N D

1 2 V

G N D

A C

T o H P G

T o H P G

T o H P G

T o M T B p a n e l
I/O m o d u le

19450

AC

HPG

GND

5V

5V

HPG

HPG

MTB

GND

GND

12V

GND

5V

BT02

PE

L2

L2

L1

L1

Connect terminals AUX-AC L1 and L2 of terminal block BT04 on the

main power supply to the color CRT power supply terminals AC L1 and

AC L2, which are located on the rear of the color operator panel, using the

power supply cable C03.

Important: The chassis ground terminal connects to the operator panel

chassis and designated cable shields. Power supply common is AC

coupled to chassis ground. It is the users responsibility to determine if a

direct connection to cabinet ground bus is required.