Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 238

Section 4D
Power Distribution and Wiring Guidelines
4D-8
Connecting Main Power Supply to the Color Operator Panel
You connect the operator panel power supply directly to the main power
supply. The operator panel power supply receives power from the color
CRT power supply through an internal jumper from the AC (L1 and L2)
terminals.
Figure 4D.6
Color Operator Panel Power Supply Connection
5 V
G N D
5 V
G N D
5 V
G N D
1 2 V
G N D
A C
T o H P G
T o H P G
T o H P G
T o M T B p a n e l
I/O m o d u le
19450
AC
HPG
GND
5V
5V
HPG
HPG
MTB
GND
GND
12V
GND
5V
BT02
PE
L2
L2
L1
L1
Connect terminals AUX-AC L1 and L2 of terminal block BT04 on the
main power supply to the color CRT power supply terminals AC L1 and
AC L2, which are located on the rear of the color operator panel, using the
power supply cable C03.
Important: The chassis ground terminal connects to the operator panel
chassis and designated cable shields. Power supply common is AC
coupled to chassis ground. It is the users responsibility to determine if a
direct connection to cabinet ground bus is required.