Section 11A

Connecting 1394 Digital Drive Systems

11A-10

E--Stop connection is made to the 1394 CNC wiring board drive okay
contactor (TB1 DROK). This relay contact is closed when 24V drive

power (W1, W2) is applied and no faults are present on the drive. This

relay is opened when a drive fault occurs or 24V drive power is lost.

DROK Specs.

115V AC/24V DC

1Amp (Inductive Load)

CNC Wiring Board

CNC Interface Board

System Module

Resolver Connectors

2

TB1

1

DROK

TB3

FB3

FB2

FB1

FB0

J4

63

(cover removed)

CNC Wiring Board

E-Stop

Connection

Important: To help you insert and remove wires on the Input Wiring

Board, the supplied “Terminal Block Operating Tool” (pictured below)

should be used as shown.

Bare, Stripped Wire

Insert (or Remove)

in Rear Slot to Release Lock

Insert Tool

11A.5

1394 Drive E-Stop

Connection (TB1)