Section 4C

Connecting the 4-axis Servo Module

4C-24

Figure 4C.16 shows an incremental feedback device equivalent circuit for

feedback channel A.

Figure 4C.16

Incremental Feedback Device Equivalent Circuit

Differential

Line Driver

Customer

Encoder

W

W

A

A

Ch A HI

Ch A LO

Termination Panel

Servo Module

8500-TPC

Cable

+5V

316

215

68pf

Zenor

Protection

Encoder Return

Optical Isolation

0V

+5V

0V

To Encoder Interface

Wiring Position Feedback

Feedback devices used with the control must be configurable such that the

marker Z is true at the same time that channels A & B are true. If you are

using an Allen-Bradley 845H encoder this requirement will already be met

if you wire them as shown in the cable diagrams on page 7A-28.

If you are using an encoder type feedback device other than the

Allen-Bradley 845H encoder, then use the following examples to

determine the correct wiring:

4C.7.1