Section 8
Communication Interface
8-18
The switch assemblies on the side and rear of the tape reader must be set as
shown below:
SIDE VIEW
REAR VIEW
____________________
___________________
|
|
|
|
12345678
|
|
ON
OFF
|
SW3
****||||
|
|
4
* -
|
||||****
|
|
3
* -
|
|
|
SW1
2
- *
|
|
|
1
* -
|
|
12
- *
|
11
- *
|
10
- *
|
9
* -
|
8
* -
|
SW2
7
* -
|
6
* -
|
5
* -
|
4
- *
|
3
- *
|
2
- *
|
1
* -
11359-I
*
Denotes switch lever location
The Decitek AB 8000-XPDR tape reader is connected to the control using
a standard RS-232 with hardware handshake interface cable (see
Figure 8.2).
5. DSI SP75 Connection
The recommended configuration of the DSI SP75 tape punch is shown
below:
Configuration
Parameter
Setting
DEVICE:
DSI SP75
PORT TYPE:
RS232C
BAUD RATE:
600
PROTOCOL:
RAW
PARITY:
EVEN
STOP BITS:
1
DATA LENGTH:
8
TIMEOUT:
15 SEC
OUTPUT CODE
ASCII
The DSI SP75 tape punch is connected to the control using a standard