5b.5.2 drive power three- phase, 9/440hr power strip – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 322

Advertising
background image

Section 5B

9/440HR CNC/Drive System

5B-32

If 24 V power is required for other devices in your machine system, you

can use a 24 V power supply in place of the 24 V transformer as shown in

Figure 5B.18.

Figure 5B.18

Connecting On/Off Power Control Assembly and 24V Power Supply

ON SW

COMMON

OFF SW

AC IN

AUX AC

AC POWER

FUSE

8A/250V

ALLEN--BRADLEY

Customer--supplied

24V Power Supply

Output 24 V ac or

24 V dc non-polarized

ON

COM

OFF

E-STOP

COM

RESET

MTB Panel

Incoming Power

85--265 V ac

DC+

INT

COL

W1

W2

U

W

V

PE

9/440HR Power Strip

PE

ON/OFF

Control Assembly

BT02

Monochrome or Color

operator panel power

supply

To local cabinet

ground bus

High

Low

Noise suppressor

199-ISMAxx

On Off Relay

Bulletin 100

A30--Nxx

15 AMP

Customer--supplied

Fuses

C

C1

L1

L2

L1

L2

PE

Three--phase power to the 9/440HR must be 324-528 V AC, 50/60 Hz.
The drive power is used to supply the drive portion of the 9/440HR the

voltages necessary to power the axis modules and the servo motors.

All power connectors on the 9/440HR power strip accept AWG 12 gauge

solid wire. Refer to local codes for required wire type and gauge.

5B.5.2

Drive Power Three- phase

Advertising