5b.5.2 drive power three- phase, 9/440hr power strip – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 322

Section 5B
9/440HR CNC/Drive System
5B-32
If 24 V power is required for other devices in your machine system, you
can use a 24 V power supply in place of the 24 V transformer as shown in
Figure 5B.18.
Figure 5B.18
Connecting On/Off Power Control Assembly and 24V Power Supply
ON SW
COMMON
OFF SW
AC IN
AUX AC
AC POWER
FUSE
8A/250V
ALLEN--BRADLEY
Customer--supplied
24V Power Supply
Output 24 V ac or
24 V dc non-polarized
ON
COM
OFF
E-STOP
COM
RESET
MTB Panel
Incoming Power
85--265 V ac
DC+
INT
COL
W1
W2
U
W
V
PE
9/440HR Power Strip
PE
ON/OFF
Control Assembly
BT02
Monochrome or Color
operator panel power
supply
To local cabinet
ground bus
High
Low
Noise suppressor
199-ISMAxx
On Off Relay
Bulletin 100
A30--Nxx
15 AMP
Customer--supplied
Fuses
C
C1
L1
L2
L1
L2
PE
Three--phase power to the 9/440HR must be 324-528 V AC, 50/60 Hz.
The drive power is used to supply the drive portion of the 9/440HR the
voltages necessary to power the axis modules and the servo motors.
All power connectors on the 9/440HR power strip accept AWG 12 gauge
solid wire. Refer to local codes for required wire type and gauge.
5B.5.2
Drive Power Three- phase