Environmental Conditions

Condition

Range or Limit

Operating temperature

CPU Board and Servo Amplifiers:

0

°

C to 55

°

C (32

°

F to 131

°

F) except 9/440

0

°

C to 50

°

C (32

°

F to 122

°

F) 9/440 only

Operator Panels (standard and removable):

0

°

C to 55

°

C (32

°

F to 131

°

F)

0

°

C to 45

°

C (32

°

F to 113

°

F) external ambient

Operator Panels (flat):

0

°

C to 50

°

C (32

°

F to 122

°

F)

0

°

C to 40

°

C (32

°

F to 104

°

F) external ambient

Operator Panels (pendant):

0

°

C to 55

°

C (32

°

F to 131

°

F)

0

°

C to 40

°

C (32

°

F to 104

°

F) external ambient

8500 Digital Servo Motors:

0

°

C to 40

°

C (32

°

F to 104

°

F)

Storage or Transport Temperature

CPU Board, Servo Motors, and Servo Amplifiers

-30

°

C to 70

°

C (-40

°

F to 158

°

F)

Operator Panel:

-30

°

C to 65

°

C (-40

°

F to 131

°

F)

Maximum Temperature Change Rate

1.1

°

C/min. (1.80

°

F/min.)

Altitude

Above temperature based on operation at 1000m (3500 ft)

Atmosphere

Components placed in a protected enclosure with filtered

air. Avoid placing components in areas where there is high

concentration of dust, cutting oil, or organic solvents.

Relative Humidity

CPU Board and Operator Panel

5-95% (no condensation)

8500 Digital Servo Motors

20-80% (no condensation)

Vibrations (operating)

Max. 1.0 G (operator panel)

Max. 2.5 G (all 9/Series controls except 9/440)

Max. 1.0 G (9/440 CNC)

Max. 2.5 G (E-150 Series I/O)

ATTENTION: Environmental conditions exceeding those

shown above may cause component failure and/or unpredictable