Section 5A
9/440 Resolver--based CNC/Drive System
5A-7
E- Stop Plug
Connection of the E--Stop string is shown in the following figure. More
details on E--Stop connections to the 9/Series are given on page 6-1.
E--Stop
Connector
TB1
E--Stop
reset
button
E--Stop
button
Customer
E--Stop
string
E--Stop status
relay contact
connection
On MTB
panel
CR
+
customer supplied
fuse (size to protect K1b
contact and your E-Stop
status relay)
1
7
9/440 Resolver--based System Module
Open Cover