Section 15A

Troubleshooting The Control

15A-28

If an 9/Series Analog I/O device is selected on the Ring I/O screen and the

{DISPLY} softkey is pressed, the Analog I/O Diagnostics screen appears.

Figure 15A.11 is an example of this screen. 1746 Analog I/O devices are

discussed on page 15A-17.

Figure 15A.11

Analog I/O Diagnostics Screen

ANALOG I/O

U:

0 TO +10

B: -10 TO +10

DEV. INPUT

OUTPUT

NO.

U/B

VAL.

VOLTAGE

U/B

VAL.

VOLTAGE

0

B

12C

1.464

U

012

0.044

1

U

52F

3.238

U

830

5.114

2

U

82C

5.104

B

800

-10.000

3

B

F12

-1.137

U

F12

9.419

6

U

800

5.000

B

012

0.088

7

B

800

-10.000

B

012

0.088

8

B

800

-10.000

B

012

0.088

9

B

800

-10.000

B

012

0.088

10

B

800

-10.000

B

012

0.088

11

B

800

-10.000

B

012

0.088

12

B

800

-10.000

B

012

0.088

The device numbers for all Analog I/O devices that are on the I/O Ring

will appear under the “ANALOG I/O” heading. These will be decimal

numbers from 00 to 15.

If more than 13 Analog I/O devices are connected to the I/O Ring, press

and hold the [SHIFT] key and press the [DOWN-ARROW] key to access

the remaining devices. Pressing these keys or cursoring below the last

device on the screen will cause the next Analog I/O Diagnostics screen to

appear.

Each device listed is followed by several columns of diagnostic values.

These columns are:

U/B

This indicates whether the device is Unipolar (0 to 10 volts) or Bipolar

(-10 to 10 volts) as determined by device switch settings.

VAL.

This is the HEX representation of the digital equivalent of the analog

voltage level from or to the device.

VOLTAGE

This is the voltage level from or to the device.

15A.4.8

Analog I/O

Diagnostics Screen