Section 8

Communication Interface

8-6

Figure 8.7

RS-232 Cable Wiring to an Allen-Bradley T50

Allen-Bradley

T50

9 Pin D-Shell

SH

SD

RD

RS

CS

GND

1

2

3

4

5

7

9/Series

15- Pin D-Shell

3

2

7

8

5

6

4

RS-422 is used for serial communication between the control and

peripherals. RS-422 is also known as complimentary serial I/O. It is

available only on port B which is located on the motherboard (for the

9/260 and 9/290 control) and on the processor board for the 9/230 control.

This signal is able to resist noise even over long distances. When you use

RS-422, the interface cable can be as long as 4000 cable feet (1220

meters). Use shielded, twisted-pair cables to resist noise.

8.4

RS-422 Interface