Section 13A

Connecting 8520 Digital Drive Systems

13A-11

Table 13A.P

3AX-D Servo Amplifier Terminal Block TB4 Terminal Assignments

Term. No.

Connection

1

TSW1-1 (For Motor 1)

2

TSW1-2 (For Motor 1)

3

TSW2-1 (For Motor 2)

4

TSW2-2 (For Motor 2)

5

TSW3-1 (For Motor 3)

6

TSW3-2 (For Motor 3)

Important: Terminal block TB4 is an optional connector that provides a

convenient connection to the thermal overload switches of the servo

amplifier. This terminal block is typically used to interface the thermal

overload switches with PAL or the system E-STOP string. The servo

amplifier operates normally without any external connections to terminal

block TB4.

This section gives you the information you need to determine which A-B

1389 transformer to use with your application. Its also gives the

dimensions of each type of A-B 1389 transformer.

Important: The 9/230, 9/260, and 9/290 8520 digital servo amplifier is

compatible only with an Allen-Bradley 1389 transformer.

Table 13A.A provides the formulas you need to size the type of

transformer for the application.

13A.3

Selecting an A-B 1389

Transformer for 8520 Digital

Servo Amplifiers