Section 15B

Replacement Procedures

15B-9

To replace the main processor board battery:

1.

Backup up any data (typically part programs, PAL, AMP, tool offsets,

axis calibration, etc.) that is resident in RAM memory.

2.

Turn OFF all power to the control.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

Important: To prevent static discharge, the use of a ground strap is

recommended .

3.

Disconnect the old battery pack from the connector on the

motherboard.

4.

Loosen the four screws holding the battery pack to the component

enclosure.

5.

Replace the old battery pack with a new one and tighten the four

screws.

6.

Connect the new battery pack to the connector CN10 on the

motherboard.

7.

Turn ON power to the control.

8.

Download the the backed up data to RAM.