Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 459

Section 8
Communication Interface
8-26
Use this table if you see a different LED pattern than shown above.
Indicator
Color/State
Description
Probable Cause
Recommended Action
A
(B is not used)
green/steady
active link
normal operation
none required
red/steady
hardware fault at
processor
hardware error
cycle power. Replace the processor.
Refer to your processor
documentation.
red/blinking
communication break
AMP is not set correctly
reset AMP parameters to
communicate with scanner program
off
remote I/O port is offline
port is not being used
bring remote I/O port on line
ACT
green/steady
active link to 9/Series
CPU
normal operation
none required
off
remote I/O module is not
communicating with
9/Series control
remote I/O module is offline
AMP or PAL is not properly
configured or your remote I/O
network is not configured to
communicate with the module.
FLT1
on
major hardware fault
device has failed
if LED remains on after cycling
power, contact your Allen-Bradley
FLT1
power, contact your Allen-Bradley
sales representative